BF / F series - semi vortex pumps

    BF series drainage and sewage submersible pump

    Selection of a suitable submersible drainage pump can be determined from the detail in the performance curve and the specification table listed below.

TYPE

Power
HP(kW)
Discharge
Inch(mm)
Phase

Start
Method

Head
m
Capacity
m3/min(m3/hr)
Head
feet
Capacity
GPM
Weight(kg)
1/3
Solid passage
mm
Dimension(mm)
Length Width Height
BF-21AP 1(0.75) 2"(50) 1 Capacitor 9 0.2(12) 30 53 19/18 27 274 235 448
3 Direct
BF-32P 2(1.5) 3"(80) 1 Capacitor 8 0.55(33) 26 146 38/36 37 418 250 549
3 Direct
BF-33P 3(2.2) 3"(80) 3 Direct 10 0.6(36) 33 159 39 40 418 250 575
BF-05U 0. 5(0.4) 2"(50) 1 Capacitor 5 0.15(9) 16 40 15 35 228 153 410
3 Direct
BF-21U 1(0.75) 2"(50) 1 Capacitor 7 0.2(12) 23 53 16 35 228 153 410
3 Direct
BF-32U 2(1.5) 3"(80) 1 Capacitor 6 0.5(30) 20 132 37/36 46 418 250 549
3 Direct
Remark: Pump of U type impeller(3phase) operates at a higher current when reverse, please adjust to fit direction of rotation.